Kent 9822 Schematic

Kent 9822

Get a print!

$8.00
Product Information:
Model:9822
Manufacturer:Kent

Schematic Pages

PNG: Page 1 Rider Manual Volume 11

Schematics Content

Page 1:

ALIGNMENT PROCEDURE
I.F. Frequency 455 KC. Set Range 540 1600 KC.
Connect the test oscillator, or signal generator, to the set as follows: Connect the " hot " side of the signal generator to the grid of the 1A7GT tube, and the ground side to the terminal on the back of the chassis. An output meter should be connected across the voice coil leads of the speaker to indicate resonance. Align the I.F. trimmers at 455 KC for maximum meter reading.
Adjust the trimmer on the back of the variable condenser at or near 1400 KC at full volume on a weak broadcast signal. When aligning the set do not set the receiver on or near a metal work bench or other large metal object, as it will affect the tracking of the receiver.