Affiliated Retailers, Inc. R-146 Schematic

Affiliated Retailers, Inc. R-146

Get a print!

$8.00
Product Information:
Model:R-146
Manufacturer:Affiliated Retailers, Inc. (Artone)

Schematic Pages

PNG: Page 1 Rider Manual Volume 17
: Page 2

Schematics Content

Page 1:

CAUTION: A GROUND CONNECTION IS NOT REQUIRED AND MUST NOT BE USED.

Frequency Range of Receiver 535 - 1700 kc
Power Requirement 105 - 125 volts 60 cycles Alternating Current (a-c) only
Power Consumption: Receiver 30 watts Record Player 35 watts

Page 2:

ALIGNMENT INSTRUCTIONS WHEN SERVICING THIS RECEIVER DO NOT PLACE CHASSIS ON A GROUNDED METALLIC BENCH.

Equipment Required:
Modulated r- f signal generator; output meter; insulated screw driver; two .1 mfd 400 volt and one 50 mmfd 400 volt condensers.

The receiver should be aligned with chassis and loop mounted in the cabinet. With the condenser completely closed the pointer should be checked so that it coincides with the two horizontal reference lines on the dial. Connect the output meter and signal generator as follows: Output meter Connect across voice coil and turn volume control to maximum.

Signal generator Connect the low side of the signal generator to the receiver chassis thru ai mfd con denser and keep the output as low as possible, then proceed in the sequence shown on the alignment chart,

Note: In case of dial light failure, replace the lamp (Mazda # 47) as soon as possible to prevent damage to the 35Z5 tube.