Transformers & Chokes

P-T166X-6D3 Transformer - Hammond, Low Voltage / Filament, Open, 6.3 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 6.3 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
Starting at $10.98
Save 0%
Originally: $10.98
P-T125XSE Transformer - Hammond, Universal Single Ended
  • Designed for general purpose or replacement use (not Hi-Fi), in single ended, tube output circuits.
  • Frequency response: 100 Hz. - 15 Khz (± 1db max. - ref. 1 Khz). (For full frequency response (20 Hz. to 20 Khz.) - see P-T1627SE).
  • For push-pull output use, see P-T125A - optimized for push-pull tube output circuits.
  • Open style with minimum 12" long primary & secondary leads leads.
  • All sizes use butt stacked cores (using 29M6 steel) with an air gap, to reduce D.C.
Starting at $45.84
P-T125X Transformer - Hammond, Universal Push-Pull
  • Designed for general purpose or replacement use in push-pull tube output circuits. (For single ended use, see our 125 SE series - optimized for single ended tube output circuits).
  • Frequency response: 150 Hz. - 15 Khz (± 1db max. ref. 1 Khz).
  • Open style with minimum 5" long primary leads, secondary solder lugs for convenient secondary connections.
  • Tables provided with transformer listing 90 pre-calculated impedance ratios.
Starting at $36.82
P-T166X-2D5 Transformer - Hammond, Low Voltage / Filament, Open, 2.5 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 2.5 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
Starting at $16.44
P-T166X-5 Transformer - Hammond, Low Voltage / Filament, Open, 5 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 5 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
Starting at $20.56
Save 0%
Originally: $20.56
P-T166N12 Transformer - Hammond, Low Voltage / Filament, Open, 12.6 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 12.6 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
$24.67
P-T167X-6D3 Transformer - Hammond, Low Voltage / Filament, Enclosed, 6.3 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 6.3 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $38.17
P-T162XSEA Transformer - Hammond, Output, Single-Ended, 30 W
  • Over designed for single ended tube output circuits (triode, tetrode or pentode tubes).
  • Enclosed (shielded), 4 slot, above chassis Type 'X' mounting.
  • Frequency response at least 20 Hz. to 20 Khz. at full rated power (± 1 db max. ref.
Starting at $151.64
P-T166X-12 Transformer - Hammond, Low Voltage / Filament, Open, 12 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 12 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
Starting at $13.64
P-T166X-10 Transformer - Hammond, Low Voltage / Filament, Open, 10 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 10 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
Starting at $28.57
Save 0%
Originally: $28.57
P-T167X-5 Transformer - Hammond, Low Voltage / Filament, Enclosed, 5 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 5 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $29.00
P-T166EA24 Transformer - Hammond, Low Voltage / Filament, Open, 24 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 24 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
$15.91
P-T166J16 Transformer - Hammond, Low Voltage / Filament, Open, 16 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 16 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
$12.14
P-T167J36 Transformer - Hammond, Low Voltage / Filament, Enclosed, 36 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 36 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$42.34
P-T262F12 Transformer - Hammond, Plate & Filament or Bias, 12.6V auxiliary
  • Primary 115 VAC, 60 Hz.
  • Designed for small power or bias supplies, test equipment, preamps etc.
  • Economical , two hole, channel bracket, chassis mount.
  • Minimum 5" long leads.
  • Convenient 12.6 filament/auxiliary winding.
$39.75
P-T167G120 Transformer - Hammond, Low Voltage / Filament, Enclosed, 120 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 120 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$41.43
P-T167X-12D6 Transformer - Hammond, Low Voltage / Filament, Enclosed, 12.6 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 12 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $29.73
P-T167S10 Transformer - Hammond, Low Voltage / Filament, Enclosed, 10 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 10 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$47.89
P-T166C50 Transformer - Hammond, Low Voltage / Filament, Open, 50 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 50 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
$24.43
P-T166X-36 Transformer - Hammond, Low Voltage / Filament, Open, 36 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 36 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
Starting at $23.87
P-T166G60 Transformer - Hammond, Low Voltage / Filament, Open, 60 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 60 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
$27.28
P-T166K18 Transformer - Hammond, Low Voltage / Filament, Open, 18 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 18 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
$16.19
P-T167X-25 Transformer - Hammond, Low Voltage / Filament, Enclosed, 25 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 25 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $37.15
P-T167L50 Transformer - Hammond, Low Voltage / Filament, Enclosed, 50 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 50 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$58.62
Don't see what you're looking for? Send us your product suggestions!