Transformers & Chokes

P-T167G120 Transformer - Hammond, Low Voltage / Filament, Enclosed, 120 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 120 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$43.50
P-TBFT-1B Transformer - One Electron, BFT-1B, Power
The BFT-1B from One Electron was designed to power a stereo amplifier using UBT-1's in each channel but will also power an 80 watt push-pull tube amplifier. The BFT-1B is slightly larger than earlier versions of the BFT-1, allowing lower flux density and cooler operation. The tapped high-voltage windings and three filament windings provide flexibility in design. An electrostatic shield between the primaries and secondaries reduces power-line noise coupling. The primary arrangements allows use on virtually any power grid in the world.
$225.00
P-TF26477 Transformer - Fender®, Power, for Tone Master
Fender® Original Tone Master Power Transformer. Equivalent to #026477.
$179.95
On Backorder
P-TM45O Transformer - Marshall, Output, for JTM45
Genuine Marshall™ output transformer for JTM45.
$135.00
P-TM950P Transformer - Marshall, Power, 50 W, for JCM 900
Genuine Marshall™ 50 watt power transformer for JCM900.
$115.00
P-T185F24 Transformer - Hammond, Global Use, Dual Primary 115/230 VAC
  • Dual primary 115/230 VAC
  • 50/60 Hz. operation
  • Dual secondaries for series or parallel connections
  • 4,000 V RMS Hipot test
  • Class F insulation (155 degrees, C)
  • Chassis mount
  • Dual bobbin construction
  • Dual use terminals
  • C UL US recognized (E207860)
  • TUV Type Approved
  • CE certified to IEC 950 (Approved to EN 60-742 Safety Isolating Transformers)
$34.31
P-T266M5 Transformer - Hammond, Power, Low V Primary / Secondary, 5V/3A
Specifications:
  • Size: 15 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 5V @ 3 A
  • Secondary VAC RMS Parallel: 2.5V @ 6 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra p
$29.54
P-T126B Transformer - Hammond, Tube Driver Interstage
Audio watts: 4
Impedance: 5k ohms
D.C. Resistance: 178 ohms
Inductance: 44 henries
Rated D.C. Bias Current: 30 mA
Features:
  • Designed for driver use ONLY in single ended tube output amplifiers. These units replace coupling capacitor circuits for improved sound.
  • Closed style with minimum 8" long leads.
  • All models use bifilar wound windings for exceptional coupling and bandwidth.
  • Minimum frequency response 20 Hz. - 20 Khz (± 1db max. ref. 1 Khz.).
  • The core is gapped to support the specified D.C.
$83.64
P-T166-50 Transformer - Hammond, Low Voltage / Filament, Open, 50 VCT
  • Open style, chassis mount transformers with a 115V 60Hz primary and a 50V center tapped secondary.
Starting at $18.75
Note:
P-T166F50: 15
P-T166G50: 25
are special order items.
Note: some of these items are special order items.
P-T166-60 Transformer - Hammond, Low Voltage / Filament, Open, 60 VCT
  • Open style, chassis mount transformers with a 115V 60Hz primary and a 60V center tapped secondary.
$22.50
P-T167J36 Transformer - Hammond, Low Voltage / Filament, Enclosed, 36 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 36 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$34.94
P-T167L50 Transformer - Hammond, Low Voltage / Filament, Enclosed, 50 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 50 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$48.36
P-T176D Transformer - Hammond, Step-Up, 500VA
Capacity: 500VA Features:
  • Single winding does not provide isolation, for use where equipment is already isolated and only voltage change is required.
  • World wide applications, 50 or 60 Hz.
$132.86
P-T182L6 Transformer - Hammond, Toroidal Power, Chassis Mount, 30VA
Specifications
  • VA: 30
  • VAC Secondary (RMS) Series: 12V C.T. @ 2.5A
  • VAC Secondary (RMS) Parallel: 6V @ 5A

Features:
  • Dual Secondary
  • Open Toroid Center
  • Low profile, lightweight, cool running - due to high efficiency toroidal design
  • Dual 117/234 VAC primary, 50/60 Hz.
$56.25
P-T229D40 Transformer - Hammond, Power, Low Voltage PC Mount
Size: 48 VA
Secondary Series: 40V C.T. @ 1.2A
Secondary Parallel: 20V @ 2.4 A
Features:
  • Low profile mounting, dual - split bobbin design.
  • Low primary to secondary coupling, balanced windings, no electrostatic shield required and low EMF radiation due to semi-toroidal design.
  • Universal dual primary 115/230V - 50/60 Hz.
  • High insulation - Hipot of 1,750V RMS.
  • Class B insulation - 130 degrees C.
  • C UL US recognized.
$25.05
P-T266G14 Transformer - Hammond, Power, Low voltage, 14V/0.5A
Specifications:
  • Size: 7 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 14V @ 0.5 A
  • Secondary VAC RMS Parallel: 7V @ 1 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra p
$23.63
P-T266J14 Transformer - Hammond, Power, Low voltage, 14V/1A
Specifications:
  • Size: 14 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 14V @ 1 A
  • Secondary VAC RMS Parallel: 7V @ 2 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra pr
$29.54
P-T266J48 Transformer - Hammond, Power, Low voltage, 48V/1A
Specifications:
  • Size: 48 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 48V @ 1 A
  • Secondary VAC RMS Parallel: 24V @ 2 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra p
$29.54
P-T266M16 Transformer - Hammond, Power, Low voltage, 16V/3A
Specifications:
  • Size: 48 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 16V @ 3 A
  • Secondary VAC RMS Parallel: 8V @ 6 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra pr
$31.50
P-T266PA6 Transformer - Hammond, Power, Low voltage, 6.3V/6A
Specifications:
  • Size: 37.8 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 6.3V @ 6 A
  • Secondary VAC RMS Parallel: 3.15V @ 12 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for e
$39.38
P-T298DT Transformer - Hammond, Line Step Up Isolation, Toroidal, 500 VA
Capacity: 500 VA
Dimensions: 9" long by 6" wide by 4" height
Features:
  • Primary 120VAC, 50/60 Hz., Secondary 240VAC.
  • Provides circuit isolation.
  • Toroidal transformer for high isolation, low noise, light weight cool operation and low profile.
  • 50 or 60 Hz.
$270.24
P-T300-Z Transformer - Hammond, High Voltage Universal Plate & Filament, Horizontal mount
  • Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
    • NOTE: units are designed to operate with BOTH primary windings engaged.
    • See primary wiring information under resources.
  • Bias Tap: 50 VAC tap from high voltage secondary C.T.
Starting at $111.62
P-T710-X Transformer - Hammond, High Voltage Plate, 115 VAC, 50 / 60 Hz
  • Primary 115 VAC, 50 / 60 Hz.
  • At 2,000 VAC and above, secondary leads are through rubber bushings
  • Units can be run full wave bridge or full wave C.T.
  • V.A. is a C.C.S. rating
  • Current ratings are CCS (Continuous Commercial Service) & ICAS ratings (Intermittent Commercial or Amateur Service).
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Class A insulation (105 degrees C).
  • Hi-Pot test at a minimum of twice secondary voltage
  • Conservative designs - CSA certified (209651).
Starting at $78.99
P-TF37610 Transformer - Fender®, Power, for '65 Twin Reverb Reissue
Made precisely to the original Fender® specifications. Drop-in replacement for '65 Twin Reverb Reissue. Made in the USA. 120V Primary.
$79.95
On Backorder