Transformers & Chokes

Special Order Item
Features:- Small, economical, open, two hole horizontal bracket mount.
- Insulated, color coded flexible leads, 4" long minimum
- Frequency response 150 Hz. to 15 Khz. (+/- 1 db, reference 1000 Hz.)
- When operating at impedances below nominal, power capability and the frequency spectrum are proportionately lower, conversely, at higher impedances power capability and frequency spectrum will be proportionately higher.
$23.32

Special Order Item
- Both series operate on 50/60 Hz current
- Low profile, split bobbin design.
- Dual winding secondaries, non-concentrically wound
- Units are designed so that all windings must be used
- Low primary to secondary coupling - no electrostatic shield required.
- High insulation - Hipot of 2,500V RMS.
- Class B insulation - 130 degrees C.
- c UL us recognized
Starting at $10.19
Low Voltage, Filament High Current, Chassis Mount. 115 V primary.
$102.21

Open style, chassis mount transformers with a 115V 60Hz primary and an 11V center tapped secondary.
Starting at $42.67

Special Order Item
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 12V secondary.
Starting at $15.06

Special Order Item
- Open style, chassis mount transformers with a 115V 60Hz primary and a 16V center tapped secondary.
Starting at $14.76

Special Order Item
Open style, chassis mount transformers with a 115V 60Hz primary and a 20V center tapped secondary.
Starting at $12.29

Open style, chassis mount transformers with a 115V 60Hz primary and a 44V center tapped secondary.
Starting at $26.37

Open style, chassis mount transformers with a 115V 60Hz primary and a 7V or 7.5V secondary.
Starting at $26.98

Open style, chassis mount transformers with a 115V 60Hz primary and a 120V center tapped secondary.
$32.62

Open style, chassis mount transformers with a 115V 60Hz primary and an 80V center tapped secondary.
$37.65

Open style, chassis mount transformers with a 115V 60Hz primary and a 35V center tapped secondary.
$42.67

Open style, chassis mount transformers with a 115V 60Hz primary and a 22V center tapped secondary.
$40.13

Open style, chassis mount transformers with a 115V 60Hz primary and a 42V center tapped secondary.
$55.24

Open style, chassis mount transformers with a 117V 50/60Hz primary and a 48V center tapped secondary.
$69.06

Open style, chassis mount transformers with a 117V 50/60Hz primary and a 72V center tapped secondary.
$75.30

- Primary 115 VAC, 60 Hz.
- Secondary 120 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
$58.24
- Primary 115 VAC, 60 Hz.
- Secondary 36 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
$46.75
- Primary 115 VAC, 60 Hz.
- Secondary 50 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
$64.71
- Primary 115 VAC, 60 Hz.
- Secondary 60 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
$45.77
- Primary 115 VAC, 60 Hz.
- Secondary 10 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
$67.30

- Primary 115 VAC, 60 Hz.
- Secondary 12 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
Starting at $27.83
- Primary 115 VAC, 60 Hz.
- Secondary 25 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
Starting at $41.03
Capacity: 100 VA
Features:
Features:
- Primary 115VAC, 60 Hz.
- Secondary taps @ 90, 100, 110, 115, 120 & 130VAC
- Electrostatic shield between primary & secondary
- Connection by flexible leads, 8" minimum length
- Perfect for critical line voltage needs (examples: older "classic" tube equipment or Japanese 100V equipment).
- CSA certified (# LR3902)
- Remember - These units do NOT convert line frequency
$80.90