Transformers & Chokes
Hammond
Hammond Manufacturing offers a full range of transformers, chokes and enclosures.
Specifications:
Features:
- Size: 37.8 VA
- Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
- Secondary VAC RMS Series: 6.3V @ 6 A
- Secondary VAC RMS Parallel: 3.15V @ 12 A
Features:
- Primary 117/234 VAC, 50/60 Hz.
- Dual secondaries
- Secondaries can be used as; a center tapped secondary, parallel connected or used individually
- Units are designed for use with all windings engaged.
- Open style.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees, C) for e
$55.32
Transformer - Hammond, Microphone Input Transformers
Studio Grade Impedance Matching, 1140 Series. Designed with Nickel alloy cores for high performance and Wide Bandwidth. Frequency Response: 20 Hz – 20 kHz ±0.35 dB, (ref. @ 1 kHz). Low distortion at levels up to +27 dBu @ 20 Hz. Excellent Shielding – Mu Metal enclosures
Starting at $91.97
- Primary 115 VAC, 60 Hz.
- Secondary 10 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
$70.67
Transformer - Hammond, Toroidal Power, 40V / 80V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 80 V series, 40 V parallel secondary.
$303.80
Transformer - Hammond, Low Voltage / Filament, Open, 24 VCT
Open style, chassis mount transformers with a 115V 60Hz or 117 50/60Hz primary and a 24V center tapped secondary.
Starting at $11.62
Transformer - Hammond, Output, replacement for Vox
- Replacements for Vox Amps
- Designed for drop in replacement of original units.
- Physically, parts were designed to look similar to original factory units (where possible).
- Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Starting at $91.00
Save 23%
Originally: $118.72
Transformer - Hammond, Guitar Amplifier, replacement for Ampeg
Part No.
Primary
Ampeg Model Names
Ampeg Part No
Bobbin/Paper Wound
VAC
Hz.
P-T291GX
120 V
60 Hz.
B25
12XA
Bobbin
P-T290CAZ
117 V
60 Hz.
Gemini VI 25W
PT 113
Bobbin
P-T290ETX
120 V
60 Hz.
Super Echo Twin
PT 109
Bobbin
P-T291HX
110 / 115 / 230 V
50 / 60 Hz.
V50H
94-270-030
Bobbin
- Replacement for Ampeg amplifiers
- Designed for drop in replacement of original units.
- Physically, parts were designed to look similar to original factory units (where possible).
- Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Part No.
Primary
Ampeg Model Names
Ampeg Part No
Bobbin/Paper Wound
VAC
Hz.
P-T291GX
120 V
60 Hz.
B25
12XA
Bobbin
P-T290CAZ
117 V
60 Hz.
Gemini VI 25W
PT 113
Bobbin
P-T290ETX
120 V
60 Hz.
Super Echo Twin
PT 109
Bobbin
P-T291HX
110 / 115 / 230 V
50 / 60 Hz.
V50H
94-270-030
Bobbin
Starting at $105.82
- Primary 115 VAC, 60 Hz.
- Secondary 36 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
$49.08
Choke - Hammond, Replacement for Vox AC30 vintage
Replacement for Vox AC30 vintage
Inductance ± 15%
30 H
D.C. Current
100 mA
Features:
Inductance ± 15%
30 H
D.C. Current
100 mA
Features:
- Designed for drop in replacement of original units.
- Physically, parts were designed to look similar to original factory units (where possible).
- Inductances measured at rated D.C. current.
- Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
- Units are vacuum impregnated with polyurethane varnish for quiet and long life operation.
$47.48
Transformer - Hammond, Line European grounded adaptor plug
Special Order Item
European plug type Used in: Austria; Belgium; Finland; France; Germany; Middle East; Netherlands; Norway; Parts of Africa, Asia ,South America, China, Tahiti and Caribbean; Sweden Features:- For use with Hammond transformers
- Heavy duty design with plastic shell & double wipe contacts.
- Indoor use only.
- Allows for ground connection between equipment and international power sources.
- Adaptors do not affect voltages, they are a mechanical device only to match foreign "pin-outs" of receptacles and/or plugs.
$13.23
Transformer - Hammond, Line Input Transformers
Studio Grade Impedance Matching, 1140 Series. Designed with Nickel alloy cores for high performance and Wide Bandwidth. Frequency Response: 20 Hz – 20 kHz ±0.35 dB, (ref. @ 1 kHz). Low distortion at levels up to +27 dBu @ 20 Hz. Excellent Shielding – Mu Metal enclosures
Starting at $83.63
Transformer - Hammond, Isolation, 115V
- Primary 115VAC, 60 Hz.
- Secondary 115VAC
- Electrostatic shield between primary & secondary
- Connection by flexible leads, 8" minimum length
- Perfect for circuit isolation or "Classic" bias power supply
- CSA certified (209651)
- Remember - These units do NOT convert line frequency
Starting at $76.73
Transformer - Hammond, Toroidal Power, 90V / 180V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 180 V series, 90 V parallel secondary.dary.
$97.65
Transformer - Hammond, Low Voltage / Filament, Open, 20 VCT
Special Order Item
Open style, chassis mount transformers with a 115V 60Hz primary and a 20V center tapped secondary.
Starting at $12.90
Transformer - Hammond, Plate & Filament or Bias, 6.3 V auxiliary
- Primary 115 VAC, 60 Hz.
- Designed for small power or bias supplies, test equipment, preamps etc.
- Models P-T261C6, P-T261E6, and P-T261G6 can also be used with full wave C.T. rectifiers.
- Economical , two hole, channel bracket, chassis mount.
- Minimum 5" long leads.
- Convenient 6.3 filament/auxiliary winding.
Starting at $40.25
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 120 V upgrade
Warning: Not all amplifier models of the same name use the same transformer model.
- Designed for drop in replacement of original units. Upgraded units with variable voltage.
- Physically, parts were designed to look similar to original factory units (where possible).
- Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
- See P-T290-FENDER-120 for 120 V basic transformers, P-T290-FENDER-240 for 240 V transformers
Warning: Not all amplifier models of the same name use the same transformer model.
Starting at $118.30
Capacity: 100 VA
Features:
Features:
- Primary 115VAC, 60 Hz.
- Secondary taps @ 90, 100, 110, 115, 120 & 130VAC
- Electrostatic shield between primary & secondary
- Connection by flexible leads, 8" minimum length
- Perfect for critical line voltage needs (examples: older "classic" tube equipment or Japanese 100V equipment).
- CSA certified (# LR3902)
- Remember - These units do NOT convert line frequency
$84.95
Transformer - Hammond, Universal Push-Pull
- Designed for general purpose or replacement use in push-pull tube output circuits. (For single ended use, see our 125 SE series - optimized for single ended tube output circuits).
- Frequency response: 150 Hz. - 15 Khz (± 1db max. ref. 1 Khz).
- Open style with minimum 5" long primary leads, secondary solder lugs for convenient secondary connections.
- Tables provided with transformer listing 90 pre-calculated impedance ratios.
Starting at $49.95
- Primary 115 VAC, 50 / 60 Hz.
- At 2,000 VAC and above, secondary leads are through rubber bushings
- Units can be run full wave bridge or full wave C.T.
- V.A. is a C.C.S. rating
- Current ratings are CCS (Continuous Commercial Service) & ICAS ratings (Intermittent Commercial or Amateur Service).
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Class A insulation (105 degrees C).
- Hi-Pot test at a minimum of twice secondary voltage
- Conservative designs - CSA certified (209651).
Starting at $111.00
Transformer - Hammond, Direct Box Transformer
Studio Grade Impedance Matching, 1140 Series. Designed with Nickel alloy cores for high performance and Wide Bandwidth. Frequency Response: 20 Hz – 20 kHz ±0.35 dB, (ref. @ 1 kHz). Low distortion at levels up to +27 dBu @ 20 Hz. Excellent Shielding – Mu Metal enclosures
$91.68
Transformer - Hammond, Power, Low V Primary / Secondary, 5V/3A
Specifications:
Features:
- Size: 15 VA
- Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
- Secondary VAC RMS Series: 5V @ 3 A
- Secondary VAC RMS Parallel: 2.5V @ 6 A
Features:
- Primary 117/234 VAC, 50/60 Hz.
- Dual secondaries
- Secondaries can be used as; a center tapped secondary, parallel connected or used individually
- Units are designed for use with all windings engaged.
- Open style.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees, C) for extra p
$41.52
Transformer - Hammond, Toroidal Power, 117V / 234V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 234 V series, 117 V parallel secondary.
Starting at $61.85
Transformer - Hammond, Low Voltage / Filament, Open, 12 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 12V center tapped secondary.
Starting at $11.62
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 120 V
Warning: Not all amplifier models of the same name use the same transformer model.
- Designed for drop in replacement of original units.
- Physically, parts were designed to look similar to original factory units (where possible).
- Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
- See P-T290-FENDER-120-UP for upgraded 120 V transformers, P-T290-FENDER-240 for 240 V transformers
Warning: Not all amplifier models of the same name use the same transformer model.
Starting at $57.49