Transformers & Chokes

P-T167X-12D6 Transformer - Hammond, Low Voltage / Filament, Enclosed, 12.6 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 12 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $34.41
P-T290-YORKVILLE Transformer - Hammond, Guitar Amplifier, replacement for Yorkville / Traynor
  • Replacement for Yorkville/Traynor amplifiers
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".

Part No. Primary Secondary 1 Secondary 2 Secondary 3 Yorkville / Traynor Amp Yorkville / Traynor Part No VAC Hz. P-T290TRA 120 V 60 Hz. 320 V @ 600 mA 60 V @ 50 mA 6.3 V.C.T. @ 9 A 100 Watt Bass A-1380 P-T290TRB 120 V 60 Hz. 620 V @ 115 mA 6.3 V.C.T. @ 115 mA YBA2-B A-1314 P-T291JX 120 V 60 Hz. 320 V @ 500 mA 60 V @ 20 mA 6.65 V.C.T.
Starting at $84.33
P-T710-X Transformer - Hammond, High Voltage Plate, 115 VAC, 50 / 60 Hz
  • Primary 115 VAC, 50 / 60 Hz.
  • At 2,000 VAC and above, secondary leads are through rubber bushings
  • Units can be run full wave bridge or full wave C.T.
  • V.A. is a C.C.S. rating
  • Current ratings are CCS (Continuous Commercial Service) & ICAS ratings (Intermittent Commercial or Amateur Service).
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Class A insulation (105 degrees C).
  • Hi-Pot test at a minimum of twice secondary voltage
  • Conservative designs - CSA certified (209651).
Starting at $87.06
P-TF41752 Transformer - Fender®, Power, Hot Rod Deville
Fender Original Hot Rod DeVille Power Transformer. Equivalent to #041752.
$85.95
P-TM950P Transformer - Marshall, Power, 50 W, for JCM 900
Genuine Marshall™ 50 watt power transformer for JCM900.
$115.00
P-T109L Transformer - Hammond, 2W Audio Miniature Epoxy Potted
Features:
  • Perfect for audio input, line matching, isolation or output transformer applications.
  • 2 watt (± 1.5 dB, 300 Hz. - 50 kHz.).
  • Epoxy potted in an attractive black molded case, Pin type P.C. board mount (min. 0.187" length).
  • Power level ratings are maximum at lowest frequency rating
  • Power can be increased slightly at higher frequencies.
  • Will withstand soldering for 10 sec. @ 260 degrees C, ambient temp. 85 degrees C max.
$29.81
P-T1182-60 Transformer - Hammond, Toroidal Power, 60V / 120V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 120 V series, 60 V parallel secondary.
Starting at $85.10
P-T166-120 Transformer - Hammond, Low Voltage / Filament, Open, 120 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 120V center tapped secondary.
$26.87
P-T166-14 Transformer - Hammond, Low Voltage / Filament, Open, 14 VCT
Open style, chassis mount transformers with a 115V 60Hz or 50/60Hz primary and a 14V center tapped secondary.
Starting at $9.19
Note:
P-T166E14:2.1
P-T166F14:3.5
P-T166G14:7
P-T166J14:14
are special order items.
Note: some of these items are special order items.
P-T166-25 Transformer - Hammond, Low Voltage / Filament, Open, 25 VCT
Open style, chassis mount transformers with a 115V 60Hz or 117 50/60Hz primary and a 25V or 25.2V center tapped secondary.
Starting at $11.05
Note:
P-T166D25:2.5
P-T166A24:0.63
P-T166E25:3.75
P-T166J25:25
P-T166J25B:25 - 117V primary
P-T166L25:50
are special order items.
Note: some of these items are special order items.
P-T166-30 Transformer - Hammond, Low Voltage / Filament, Open, 30 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 30 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
Starting at $20.67
Note: P-T166E30: 4.5 is a special order item.
P-T166-33 Transformer - Hammond, Low Voltage / Filament, Open, 33 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 33V center tapped secondary.
$24.81
P-T166-35 Transformer - Hammond, Low Voltage / Filament, Open, 35 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 35V center tapped secondary.
$35.14
P-T166-9 Transformer - Hammond, Low Voltage / Filament, Open, 9 VCT
Special Order Item
Open style, chassis mount transformers with a 115V 60Hz primary and a 9V center tapped secondary.
$22.22
Note: special order items require additional lead time. See our page on special order items.
P-T167S10 Transformer - Hammond, Low Voltage / Filament, Enclosed, 10 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 10 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$55.43
P-T167X-5 Transformer - Hammond, Low Voltage / Filament, Enclosed, 5 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 5 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $33.57
P-T169C Transformer - Hammond, Isolation, 100VA
Capacity: 100 VA
Features:
  • Primary 115VAC, 60 Hz.
  • Secondary taps @ 90, 100, 110, 115, 120 & 130VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for critical line voltage needs (examples: older "classic" tube equipment or Japanese 100V equipment).
  • CSA certified (# LR3902)
  • Remember - These units do NOT convert line frequency
$66.63
P-T300-Z Transformer - Hammond, High Voltage Universal Plate & Filament, Horizontal mount
  • Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
    • NOTE: units are designed to operate with BOTH primary windings engaged.
    • See primary wiring information under resources.
  • Bias Tap: 50 VAC tap from high voltage secondary C.T.
Starting at $101.51
P-T850-X Transformer - Hammond, Audio Broadcast Quality, 850A Series
Deep-drawn steel case with tin plated finish, with two convenient 6-32 mounting studs with mounting hardware. Sealed case and wax potted core internally for stable characteristics and long life. Wide frequency response +/- 0.5 db max. from 20 Hz. to 20 Khz. (except units over 5K ohms impedance, may be down 1 db @ 20 Khz.) Insertion loss of apx. 1 db.
$132.76
P-TBFT-1B Transformer - One Electron, BFT-1B, Power
The BFT-1B from One Electron was designed to power a stereo amplifier using UBT-1's in each channel but will also power an 80 watt push-pull tube amplifier. The BFT-1B is slightly larger than earlier versions of the BFT-1, allowing lower flux density and cooler operation. The tapped high-voltage windings and three filament windings provide flexibility in design. An electrostatic shield between the primaries and secondaries reduces power-line noise coupling. The primary arrangements allows use on virtually any power grid in the world.
$225.00
P-TF26477 Transformer - Fender®, Power, for Tone Master
Fender® Original Tone Master Power Transformer. Equivalent to #026477.
$189.95
On Backorder
P-C194TB Choke - Hammond, replacement for Vox TB35C2
16H @ 40 mA guitar amplifier replacement for Vox TB35C2 Tony Bruno. Physically, parts were designed to look similar to original factory units (where possible). Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
$23.97
P-T1140-MS-X Transformer - Hammond, Microphone Splitter Transformers
Studio Grade Impedance Matching, 1140 Series. ​Designed with Nickel alloy cores for high performance and Wide Bandwidth. Frequency Response: 20 Hz – 20 kHz ±0.35 dB, (ref. @ 1 kHz). Low distortion at levels up to +27 dBu @ 20 Hz. Excellent Shielding – Mu Metal enclosures
Starting at $59.11
P-T1182-117 Transformer - Hammond, Toroidal Power, 117V / 234V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 234 V series, 117 V parallel secondary.
Starting at $48.51
Don't see what you're looking for? Send us your product suggestions!