P-T298G4 Transformer - Hammond, Line European grounded adaptor plug
Special Order Item
Europeon plug type Used in: Austria; Belgium; Finland; France; Germany; Middle East; Netherlands; Norway; Parts of Africa, Asia ,South America, China, Tahiti and Caribbean; Sweden Features:
  • For use with Hammond transformers
  • Heavy duty design with plastic shell & double wipe contacts.
  • Indoor use only.
  • Allows for ground connection between equipment and international power sources.
  • Adaptors do not affect voltages, they are a mechanical device only to match foreign "pin-outs" of receptacles and/or plugs.
$8.57
Note: special order items require additional lead time. See our page on special order items.
P-T300-Z Transformer - Hammond, High Voltage Universal Plate & Filament, Horizontal mount
  • Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
    • NOTE: units are designed to operate with BOTH primary windings engaged.
    • See primary wiring information under resources.
  • Bias Tap: 50 VAC tap from high voltage secondary C.T.
Starting at $111.62
P-T710-X Transformer - Hammond, High Voltage Plate, 115 VAC, 50 / 60 Hz
  • Primary 115 VAC, 50 / 60 Hz.
  • At 2,000 VAC and above, secondary leads are through rubber bushings
  • Units can be run full wave bridge or full wave C.T.
  • V.A. is a C.C.S. rating
  • Current ratings are CCS (Continuous Commercial Service) & ICAS ratings (Intermittent Commercial or Amateur Service).
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Class A insulation (105 degrees C).
  • Hi-Pot test at a minimum of twice secondary voltage
  • Conservative designs - CSA certified (209651).
Starting at $78.99
P-RC-3 Choke - One Electron, Audio, PRC-3, 225H for Preamp Output
The PRC-3 audio choke from One Electron was designed as a plate load for the output of either a high quality line amplifier or a phono preamp.
$69.95
P-C1536X Choke - 0.17 - 250, Heavy Duty Hash Choke
Molded powdered iron core.
1-1/4 long axial leads.
High inductance & high current.
L measured at 1 Khz. Inductance: 250 µH20% tolerance
DC resistance ohms: .17
Self Resonant Frequency (MHz): 1.5
Maximum DC current amps: 2.5
Coil diameter (in): .43
Core Length (in): 1.25
$1.08
P-T118944 Transformer - Hammond, Radiola III-A Replacement Audio
Developed in response to requests from RCA Radiola III-A collectors. The original transformers are usually found with open" windings due to the fine wire and high turns usedcoupled with age. This is a universal replacement type - it will replace any of the three audio transformers used (1st audio driver2nd audio-phase splitter stage or output transformer)by correctly connectiong the 5 lugs. A pin out and connection diagram is included. The cases from the old transformer will fit this new unit. The terminal board is a duplicate of the original.
Key Features
  • Primary: 4000 turns, #41 wire (lugs 4 & 2)
  • Secondary: 12000 turns C.T., #41 wire (lugs 5 & 1lug 3 is C.T. connection)
  • Termination: Solder lugs on a 1 3/4" x 1" terminal board with 4-5" connecting leads
  • Size: 1-7/8" long x 1-11/16" wide x 1-3/8" deep
  • Lamination Core Size: 5/8" x 1/2"
  • Weight: 7 oz.
$48.25
P-T119DA Transformer - Hammond, Audio Interstage, 12 Watt
Developed in response to requests from the Collins Collectors Association"this is a matching audio transformer for older equipment with 600 ohm audio outputdriving modern speakers. Or for "classic" high impedance speakers used with newer equipmentsimply swap primary for secondary (ie...4 or 8 ohm input and 600 ohms out). Key Features Isolation unit: (i.e.
$30.16
P-T125H Transformer - Hammond, Output, 8 W, 10k Primary
Specifications Audio Watts: 8 watts Primary Impendance (Ohms): 10K center-tapped Secondary Impendance (Ohms): 2/4/8 Mounting centers: 2-3/8u-bracket Weight: 1.0 lbs. Cat. No. Dimensions (Inches) A B C D G Mtg. Hole 125H 2.81 1.4 1.7 2.36 0.187
$37.00
P-T125J Transformer - Hammond, Output, 8 W, 2.5k or 4k Primary
Specifications Audio Watts: 8 Primary Impendance (Ohms): 2.5k/4K center-tapped Secondary Impendance (Ohms): 6/8 - 3.2/4 Mounting centers: 2-13/16u-bracket Weight: 1.0 lb.
$36.99
P-T143 Transformer - Hammond, Power, 350-0-350V, 70-90 mA
Custom manufactured to replace most 6 and 7 tube sets of the early 1930s. Supplied with vertical mounting shells. Provides a seperate filament winding for audio output stages.
Specifications
Rating: 350-0-350 V, 70 or 90 mA (if 5 V winding is used with 2 A rectifier)
Windings: 5 V, 3 A; 2.5 V, 7.5 A; 2.5 VCT, 3.5 A
Mounting Centers:2 x 2.625"
Weight: 4.2 lbs.
Overall Height: 3.12"
$105.95
P-T166-10 Transformer - Hammond, Low Voltage / Filament, Open, 10 VCT
  • Open style, chassis mount transformers with a 115V 60Hz primary and a 10V center tapped secondary
Starting at $10.85
Note:
P-T166F10: 3
P-T166L10: 20
are special order items.
Note: some of these items are special order items.
P-T167X-12D6 Transformer - Hammond, Low Voltage / Filament, Enclosed, 12.6 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 12 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $31.22
P-T167X-5 Transformer - Hammond, Low Voltage / Filament, Enclosed, 5 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 5 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $30.45
P-T167S10 Transformer - Hammond, Low Voltage / Filament, Enclosed, 10 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 10 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$50.28
P-T167X-6D3 Transformer - Hammond, Low Voltage / Filament, Enclosed, 6.3 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 6.3 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $31.49
P-T169XS Transformer - Hammond, Isolation, 115V
  • Primary 115VAC, 60 Hz.
  • Secondary 115VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for circuit isolation or "Classic" bias power supply
  • CSA certified (209651)
  • Remember - These units do NOT convert line frequency
Starting at $54.60
P-T171X Transformer - Hammond, Isolation / plug & receptacle
  • Primary 115VAC, 50 / 60 Hz., Secondary 115VAC
  • Provides complete circuit isolation.
  • Electrostatic shield between primary & secondary to greatly attenuate surges and noise.
  • Hi-pot tested to 2 KV RMS.
  • Circuit breaker in primary.
  • Standard 3-wire, grounded plug & receptacle.
  • Input (primary) connected to 5 foot long cord & standard North American plug (NEMA 5-15P).
  • Output (secondary) connected to 1 foot long "pig tail" cord, 3-wire, standard North American grounded receptacle (NEMA 5-15R).
  • North American Mark of Safety - C UL & UL listed (File #E211544)
  • Indoor use only
  • Remember - These units do NOT convert line frequency
Starting at $87.42
P-T266M5 Transformer - Hammond, Power, Low V Primary / Secondary, 5V/3A
Specifications:
  • Size: 15 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 5V @ 3 A
  • Secondary VAC RMS Parallel: 2.5V @ 6 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra p
$29.54
P-T270CBX Transformer - Hammond, Power, 250-0-250 V, 100 mA
Primary 115 VAC 60 Hz.
Secondary DC current measured with cap. input filter, full wave (two diode) C.T., rectifier circuit.
Enclosed, 4 hole chassis mount.
Minimum 6 long leads.
2" X 2" vertical mounting centers.
Class A insulation (105 degrees C).
Hi-Pot test of 2000 V RMS.
Conservative designs - CSA certified (# LR3902).
3.2lbs
Secondary: 250-0-250 V100 mA
Filament winding 1: 5 V2 A
Filament winding 2: 6.3 V3 A
$65.31
On Backorder
P-T263-Z Transformer - Hammond, High Voltage Plate & Filament, Horizontal mount
  • Horizontal mount. For Vertical Mount, see P-T263-X
  • Primary 117 VAC, 50/60 Hz. - except as noted
  • Enclosed, 4 hole, chassis mount.
  • Minimum 6" long leads.
  • Units can be run full wave bridge or full wave C.T.
  • Class A insulation (105 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • Conservative designs - CSA certified (209651).
  • For Vertical Mount, see P-T263-X
Starting at $67.25
P-T431 Transformer - Audio Interstage, Coil Assembly for P-T156
Coil assembly for P-T156. Use your own iron to preserve mechanical fit. Coil window is 1/2 x ½".
$14.75
P-TN-51X Transformer - Isolation, 35 VA, 115V, 300 mA, 1 x 115V
35VA chassis mount Power Transformer for isolating equipment from direct connection to the power line. It is constructed with non-concentrically wound coils. The primary and secondary are wound on separate arbors, then assembled on a laminate core side-by-side separated by insulation. This prevents electrical connection under normal or overload conditions between the primary and secondary windings. These units are designed with 1500V isolation between winding to winding and between winding and core. Materials and construction are rated for Class B insulation system.
$21.95
P-T185F24 Transformer - Hammond, Global Use, Dual Primary 115/230 VAC
  • Dual primary 115/230 VAC
  • 50/60 Hz. operation
  • Dual secondaries for series or parallel connections
  • 4,000 V RMS Hipot test
  • Class F insulation (155 degrees, C)
  • Chassis mount
  • Dual bobbin construction
  • Dual use terminals
  • C UL US recognized (E207860)
  • TUV Type Approved
  • CE certified to IEC 950 (Approved to EN 60-742 Safety Isolating Transformers)
$34.31
P-T124X Transformer - Hammond, Audio Interstage, 5 Watt
  • Designed for general purpose or replacement use in push-pull or phase inverter tube driver circuits.
  • Should not be used for single ended applications. They have no gap for DC bias current present in SE mode.
  • Open style with minimum 5" long primary leads.
  • Minimum frequency response 150 Hz. - 15 Khz (+/- 1db max. ref. 1 Khz.) at full rated power.
  • Core material is Grain Oriented Silicon Steel.
Starting at $38.60