Transformers & Chokes

Hammond

Hammond Manufacturing offers a full range of transformers, chokes and enclosures.
P-C194A Choke - Hammond, for Fender Deluxe, Deluxe Reverb, etc.
Replacement for Fender Deluxe, Deluxe Reverb, Vibrolux, Vibrolux Reverb Equivalent to Manufacturer part number 125C3A & 022707 Specifications: Inductance ± 15% 4 H D.C. Current 50 mA Features:
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Inductances measured at rated D.C. current.
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • Units are vacuum impregnated with polyurethane varnish for quiet and long life operation.
$21.95
Transformer - Hammond, Power, Low voltage, 12.6V/4A
Specifications:
  • Size: 50.4 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 12.6V @ 4 A
  • Secondary VAC RMS Parallel: 6.3V @ 8 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for ex
$47.02
P-T140-X Transformer - Hammond, Studio Grade Impedance Matching, 140 Series
Studio grade frequency response: 20 Hz. - 20 Khz. (+/- 1 db, ref. @ 1 Khz.) minimum. Excellent frequency response utilizing a 80% nickel core providing high permeability combined with low losses. Designed for maximum bandwidth, lowest distortion at +10 dbm power level or less. Plated steel cans, adjustable height case bracket.
Starting at $82.70
P-T167X-5 Transformer - Hammond, Low Voltage / Filament, Enclosed, 5 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 5 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $42.78
P-T1182-30 Transformer - Hammond, Toroidal Power, 30V / 60V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 60 V series, 30 V parallel secondary.
Starting at $70.53
P-T166-25 Transformer - Hammond, Low Voltage / Filament, Open, 25 VCT
Open style, chassis mount transformers with a 115V 60Hz or 117 50/60Hz primary and a 25V or 25.2V center tapped secondary.
Starting at $9.54
Save 38%
Originally: $15.50
Note:
P-T166D25:2.5
P-T166A24:0.63
P-T166E25:3.75
P-T166J25:25
P-T166J25B:25 - 117V primary
P-T166L25:50
are special order items.
Note: some of these items are special order items.
P-T1750X-MARSHALL Transformer - Hammond, Output, replacement for Marshall
  • Replacements for Marshall Amps
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Starting at $49.95
P-T290-FENDER-240 Transformer - Hammond, Guitar Amplifier, replacement for Fender, 240 V
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120 for 120 V transformers, P-T290-Fender-120-UP for upgraded 120 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Starting at $63.25
Transformer - Hammond, Low Voltage / Filament, Enclosed, 25 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 25 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $43.08
P-C194D Choke - Hammond, Replacement for Vox AC30 reissue
Replacement for Vox AC30 reissue


Inductance ± 15%
5 H


D.C. Current
150 mA


Features:
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Inductances measured at rated D.C. current.
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • Units are vacuum impregnated with polyurethane varnish for quiet and long life operation.
$52.00
Transformer - Hammond, Line Step Up Isolation, Toroidal, 500 VA
Capacity: 500 VA
Dimensions: 9" long by 6" wide by 4" height
Features:
  • Primary 120VAC, 50/60 Hz., Secondary 240VAC.
  • Provides circuit isolation.
  • Toroidal transformer for high isolation, low noise, light weight cool operation and low profile.
  • 50 or 60 Hz.
$379.17
P-T1140-MS-X Transformer - Hammond, Microphone Splitter Transformers
Studio Grade Impedance Matching, 1140 Series. ​Designed with Nickel alloy cores for high performance and Wide Bandwidth. Frequency Response: 20 Hz – 20 kHz ±0.35 dB, (ref. @ 1 kHz). Low distortion at levels up to +27 dBu @ 20 Hz. Excellent Shielding – Mu Metal enclosures
Starting at $75.35
P-T167X-6D3 Transformer - Hammond, Low Voltage / Filament, Enclosed, 6.3 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 6.3 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $44.23
Note: P-T167U6: 16 A is a special order item.
P-T1182-60 Transformer - Hammond, Toroidal Power, 60V / 120V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 120 V series, 60 V parallel secondary.
Starting at $108.48
P-T166L22 Transformer - Hammond, Low Voltage / Filament, Open, 22 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 22V center tapped secondary.
$42.13
P-T193X Filter Choke - Hammond, D.C. choke, Enclosed
  • Enclosed, 4-hole mount chokes
  • Tolerance of 15% on both inductance & resistance.
  • Inductances measured at rated D.C. current.
  • Minimum 8" long leads.
  • Units will exhibit less inductance at slightly higher currents or more at lower currents.
  • Perfect for high voltage power supply filtering, case matches power transformers & tube audio output transformers.
  • Units are vacuum impregnated with polyurethane varnish for quiet and long life operation.
  • For more sizes and voltages (open - bracket mount type) - see P-T154-P-T156-X
  • Operating temperature range is -40C to 85C
Starting at $47.57
Save 10%
Originally: $52.95
Note: P-T193T: 0.05 H / 2 A is a special order item.
P-T290-YORKVILLE Transformer - Hammond, Guitar Amplifier, replacement for Yorkville / Traynor
  • Replacement for Yorkville/Traynor amplifiers
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".

Part No. Primary Secondary 1 Secondary 2 Secondary 3 Yorkville / Traynor Amp Yorkville / Traynor Part No VAC Hz. P-T290TRA 120 V 60 Hz. 320 V @ 600 mA 60 V @ 50 mA 6.3 V.C.T. @ 9 A 100 Watt Bass A-1380 P-T290TRB 120 V 60 Hz. 620 V @ 115 mA 6.3 V.C.T. @ 115 mA YBA2-B A-1314 P-T291JX 120 V 60 Hz. 320 V @ 500 mA 60 V @ 20 mA 6.65 V.C.T.
Starting at $107.52
Transformer - Hammond, Low Voltage / Filament, Enclosed, 50 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 50 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$67.95
P-T124X Transformer - Hammond, Audio Interstage, 5 Watt
  • Designed for general purpose or replacement use in push-pull or phase inverter tube driver circuits.
  • Should not be used for single ended applications. They have no gap for DC bias current present in SE mode.
  • Open style with minimum 5" long primary leads.
  • Minimum frequency response 150 Hz. - 15 Khz (+/- 1db max. ref. 1 Khz.) at full rated power.
  • Core material is Grain Oriented Silicon Steel.
Starting at $54.23
Transformer - Hammond, High Voltage Universal Plate & Filament, Horizontal mount
  • Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
    • NOTE: units are designed to operate with BOTH primary windings engaged.
    • See primary wiring information under resources.
  • Bias Tap: 50 VAC tap from high voltage secondary C.T.
Starting at $129.42
P-T1140-LU-X Transformer - Hammond, Line Output Transformers
Studio Grade Impedance Matching, 1140 Series. ​Designed with Nickel alloy cores for high performance and Wide Bandwidth. Frequency Response: 20 Hz – 20 kHz ±0.35 dB, (ref. @ 1 kHz). Low distortion at levels up to +27 dBu @ 20 Hz. Open Style
Starting at $44.17
P-T171X Transformer - Hammond, Isolation / plug & receptacle
  • Primary 115VAC, 50 / 60 Hz., Secondary 115VAC
  • Provides complete circuit isolation.
  • Electrostatic shield between primary & secondary to greatly attenuate surges and noise.
  • Hi-pot tested to 2 KV RMS.
  • Circuit breaker in primary.
  • Standard 3-wire, grounded plug & receptacle.
  • Input (primary) connected to 5 foot long cord & standard North American plug (NEMA 5-15P).
  • Output (secondary) connected to 1 foot long "pig tail" cord, 3-wire, standard North American grounded receptacle (NEMA 5-15R).
  • North American Mark of Safety - C UL & UL listed (File #E211544)
  • Indoor use only
  • Remember - These units do NOT convert line frequency
Starting at $122.85
P-T1182-110 Transformer - Hammond, Toroidal Power, 110V / 220V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 220 V series, 110 V parallel secondary.
Starting at $57.68
P-T166-14 Transformer - Hammond, Low Voltage / Filament, Open, 14 VCT
Open style, chassis mount transformers with a 115V 60Hz or 50/60Hz primary and a 14V center tapped secondary.
Starting at $12.90
Note:
P-T166E14:2.1
P-T166F14:3.5
P-T166G14:7
P-T166J14:14
are special order items.
Note: some of these items are special order items.
Don't see what you're looking for? Send us your product suggestions!