Transformers & Chokes

Fender

Fender® - Founded in Fullerton California by Leo Fender, Fender Musical Instruments Corp is the world's foremost manufacturer of guitars, basses, amplifiers and related equipment dating back to the 1940's.

Hammond

Hammond Manufacturing offers a full range of transformers, chokes and enclosures.

Triad Magnetics

Triad magnetics is a custom manufacturer of transformers and inductors.
P-T167L50 Transformer - Hammond, Low Voltage / Filament, Enclosed, 50 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 50 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$52.76
Save 10%
Originally: $58.62
P-T169C Transformer - Hammond, Isolation, 100VA
Capacity: 100 VA
Features:
  • Primary 115VAC, 60 Hz.
  • Secondary taps @ 90, 100, 110, 115, 120 & 130VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for critical line voltage needs (examples: older "classic" tube equipment or Japanese 100V equipment).
  • CSA certified (# LR3902)
  • Remember - These units do NOT convert line frequency
$65.94
Save 10%
Originally: $73.27
P-T176D Transformer - Hammond, Step-Up, 500VA
Capacity: 500VA Features:
  • Single winding does not provide isolation, for use where equipment is already isolated and only voltage change is required.
  • World wide applications, 50 or 60 Hz.
$144.93
Save 10%
Originally: $161.03
P-T182L6 Transformer - Hammond, Toroidal Power, Chassis Mount, 30VA
Specifications
  • VA: 30
  • VAC Secondary (RMS) Series: 12V C.T. @ 2.5A
  • VAC Secondary (RMS) Parallel: 6V @ 5A

Features:
  • Dual Secondary
  • Open Toroid Center
  • Low profile, lightweight, cool running - due to high efficiency toroidal design
  • Dual 117/234 VAC primary, 50/60 Hz.
$61.35
Save 10%
Originally: $68.17
P-T186E10 Transformer - Hammond, Low Voltage, Single Primary, 10V 5A
Secondary VAC: 10V C.T.
Current: 5 A
VA Rating: 50
Features:
  • Single Primary 115VAC
  • Operates on 50/60 Hz.
  • Combination solder or quick connect terminals.
  • Split bobbin construction eliminates the need for an electrostatic shield.
  • Hi-pot tested to 2 KV RMS.
  • Economical open style, channel frame - chassis mount design
  • UL recognized & CSA certified.
$17.21
Save 10%
Originally: $19.12
P-T187X Transformer - Hammond, Low Voltage, Single Primary, 120VCT
  • Single Primary 115VAC
  • Operates on 50/60 Hz.
  • Combination solder or quick connect terminals.
  • Split bobbin construction eliminates the need for an electrostatic shield.
  • Hi-pot tested to 2 KV RMS.
  • Economical open style, channel frame - chassis mount design
  • UL recognized & CSA certified.
Starting at $9.22
Save 10%
Originally: $10.25
P-T187E12 Transformer - Hammond, Low Voltage, Dual Primary, 12.6V 4A
Secondary VAC: 12.6V C.T.
Current: 4 A
VA Rating: 50.4
Features:
  • Dual Primary 115/230VAC
  • Operates on 50/60 Hz.
  • Combination solder or quick connect terminals.
  • Split bobbin construction eliminates the need for an electrostatic shield.
  • Hi-pot tested to 2 KV RMS.
  • Economical open style, channel frame - chassis mount design
  • UL recognized & CSA certified.
$17.58
Save 10%
Originally: $19.53
P-T229D40 Transformer - Hammond, Power, Low Voltage PC Mount
Size: 48 VA
Secondary Series: 40V C.T. @ 1.2A
Secondary Parallel: 20V @ 2.4 A
Features:
  • Low profile mounting, dual - split bobbin design.
  • Low primary to secondary coupling, balanced windings, no electrostatic shield required and low EMF radiation due to semi-toroidal design.
  • Universal dual primary 115/230V - 50/60 Hz.
  • High insulation - Hipot of 1,750V RMS.
  • Class B insulation - 130 degrees C.
  • C UL US recognized.
$27.32
Save 10%
Originally: $30.35
P-T260X Transformer - Hammond, Plate & Filament
  • Universal primary with taps for 100, 120, 220 or 240 VAC, 50 / 60 Hz. (Except the 260A6 which is 117V, 50/60 Hz only)
  • Designed for preamps, low power amps, general replacement, test equipment, etc.
  • Economical, open frame, chassis mount - two hole (.187 dia. = G) channel bracket (figure #1) or four hole mounting (figure #2).
  • Units include a Faraday shield between the primary and secondary windings. Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries.
  • Minimum 5" long leads.
  • For more selection check out our P-T300-X series of universal plate & filament transformers.
Starting at $69.08
Save 10%
Originally: $76.76
P-T266G14 Transformer - Hammond, Power, Low voltage, 14V/0.5A
Specifications:
  • Size: 7 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 14V @ 0.5 A
  • Secondary VAC RMS Parallel: 7V @ 1 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra p
$25.78
Save 10%
Originally: $28.64
P-T266G36 Transformer - Hammond, Power, Low voltage, 36V/0.5A
Specifications:
  • Size: 18 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 36V @ 0.5 A
  • Secondary VAC RMS Parallel: 18V @ 1 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra
$34.37
Save 10%
Originally: $38.19
P-T266J14 Transformer - Hammond, Power, Low voltage, 14V/1A
Specifications:
  • Size: 14 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 14V @ 1 A
  • Secondary VAC RMS Parallel: 7V @ 2 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra pr
$32.22
Save 10%
Originally: $35.80
P-T266J48 Transformer - Hammond, Power, Low voltage, 48V/1A
Specifications:
  • Size: 48 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 48V @ 1 A
  • Secondary VAC RMS Parallel: 24V @ 2 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra p
$32.22
Save 10%
Originally: $35.80
P-T266M16 Transformer - Hammond, Power, Low voltage, 16V/3A
Specifications:
  • Size: 48 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 16V @ 3 A
  • Secondary VAC RMS Parallel: 8V @ 6 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra pr
$34.37
Save 10%
Originally: $38.19
P-T266N12 Transformer - Hammond, Power, Low voltage, 12.6V/4A
Specifications:
  • Size: 50.4 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 12.6V @ 4 A
  • Secondary VAC RMS Parallel: 6.3V @ 8 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for ex
$36.51
Save 10%
Originally: $40.57
P-T266PA6 Transformer - Hammond, Power, Low voltage, 6.3V/6A
Specifications:
  • Size: 37.8 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 6.3V @ 6 A
  • Secondary VAC RMS Parallel: 3.15V @ 12 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for e
$42.96
Save 10%
Originally: $47.73
P-T298DT Transformer - Hammond, Line Step Up Isolation, Toroidal, 500 VA
Capacity: 500 VA
Dimensions: 9" long by 6" wide by 4" height
Features:
  • Primary 120VAC, 50/60 Hz., Secondary 240VAC.
  • Provides circuit isolation.
  • Toroidal transformer for high isolation, low noise, light weight cool operation and low profile.
  • 50 or 60 Hz.
$294.80
Save 10%
Originally: $327.56
P-T298G4 Transformer - Hammond, Line European grounded adaptor plug
Europeon plug type Used in: Austria; Belgium; Finland; France; Germany; Middle East; Netherlands; Norway; Parts of Africa, Asia ,South America, China, Tahiti and Caribbean; Sweden Features:
  • For use with Hammond transformers
  • Heavy duty design with plastic shell & double wipe contacts.
  • Indoor use only.
  • Allows for ground connection between equipment and international power sources.
  • Adaptors do not affect voltages, they are a mechanical device only to match foreign "pin-outs" of receptacles and/or plugs.
$9.34
Save 10%
Originally: $10.38
P-T373AZ Transformer - Hammond, Power, 325-0-325 V, 46 mA, Univ. Primary
  • Universal Primary - 100, 110, 120, 200, 220, 240 VAC 50/60 Hz.
  • High voltage secondary designed for full wave center tapped use.
  • 50 VAC bias tap from high voltage secondary C.T.
  • Black epoxy painted to match our P-T1650 series of output transformers .
  • Class A insulation (105 degrees C).
  • Hi-Pot tested to 2,500 VAC.
  • Windings are concentric wound for low stray field and low noise.

Secondary: 325-0-325 V, 46 mA Filament winding 1 : 5 VCT, 2 A Filament winding 2 : 6.3 VCT, 2 A Mounting centers: horizontal mount Weight: 2.5 lbs.
$110.50
Save 10%
Originally: $122.78
P-T710-X Transformer - Hammond, High Voltage Plate, 115 VAC, 50 / 60 Hz
  • Primary 115 VAC, 50 / 60 Hz.
  • At 2,000 VAC and above, secondary leads are through rubber bushings
  • Units can be run full wave bridge or full wave C.T.
  • V.A. is a C.C.S. rating
  • Current ratings are CCS (Continuous Commercial Service) & ICAS ratings (Intermittent Commercial or Amateur Service).
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Class A insulation (105 degrees C).
  • Hi-Pot test at a minimum of twice secondary voltage
  • Conservative designs - CSA certified (209651).
Starting at $86.17
Save 10%
Originally: $95.75
P-T850LA Transformer - Hammond, Audio Broadcast Quality
Output to Line, Matching or Bridging
  • Deep-drawn steel case with tin plated finish, with two convenient 6-32 mounting studs with mounting hardware.
  • Sealed case and wax potted core internally for stable characteristics and long life.
  • Wide frequency response ± 0.5 db max. from 20 Hz. to 20 Khz. (except units over 5K ohms impedance, may be down 1 db @ 20 Khz.)
  • Insertion loss of apx. 1 db.
  • Maximum power level +15 dbm. with specified characteristics, or higher levels with reduced low frequency performance.
  • Distortion is apx. 1.5% @ 20 Hz.
$131.60
Save 10%
Originally: $146.22
P-T118944 Transformer - Hammond, Radiola III-A Replacement Audio
Developed in response to requests from RCA Radiola III-A collectors. The original transformers are usually found with open" windings due to the fine wire and high turns usedcoupled with age. This is a universal replacement type - it will replace any of the three audio transformers used (1st audio driver2nd audio-phase splitter stage or output transformer)by correctly connectiong the 5 lugs. A pin out and connection diagram is included. The cases from the old transformer will fit this new unit. The terminal board is a duplicate of the original.
Key Features
  • Primary: 4000 turns, #41 wire (lugs 4 & 2)
  • Secondary: 12000 turns C.T., #41 wire (lugs 5 & 1lug 3 is C.T. connection)
  • Termination: Solder lugs on a 1 3/4" x 1" terminal board with 4-5" connecting leads
  • Size: 1-7/8" long x 1-11/16" wide x 1-3/8" deep
  • Lamination Core Size: 5/8" x 1/2"
  • Weight: 7 oz.
$43.43
Save 10%
Originally: $48.25
P-T119DA Transformer - Hammond, Audio Interstage, 12 Watt
Developed in response to requests from the Collins Collectors Association"this is a matching audio transformer for older equipment with 600 ohm audio outputdriving modern speakers. Or for "classic" high impedance speakers used with newer equipmentsimply swap primary for secondary (ie...4 or 8 ohm input and 600 ohms out). Key Features Isolation unit: (i.e.
$27.14
Save 10%
Originally: $30.16
P-T125H Transformer - Hammond, Output, 8 W, 10k Primary
Specifications Audio Watts: 8 watts Primary Impendance (Ohms): 10K center-tapped Secondary Impendance (Ohms): 2/4/8 Mounting centers: 2-3/8u-bracket Weight: 1.0 lbs. Cat. No. Dimensions (Inches) A B C D G Mtg. Hole 125H 2.81 1.4 1.7 2.36 0.187
$33.30
Save 10%
Originally: $37.00
Don't see what you're looking for? Send us your product suggestions!