P-T187X Transformer - Hammond, Low Voltage, Single Primary, 120VCT
Special Order Item
  • Single Primary 115VAC
  • Operates on 50/60 Hz.
  • Combination solder or quick connect terminals.
  • Split bobbin construction eliminates the need for an electrostatic shield.
  • Hi-pot tested to 2 KV RMS.
  • Economical open style, channel frame - chassis mount design
  • UL recognized & CSA certified.
Starting at $10.25
Note: special order items require additional lead time. See our page on special order items.
P-T187E12 Transformer - Hammond, Low Voltage, Dual Primary, 12.6V 4A
Special Order Item
Secondary VAC: 12.6V C.T.
Current: 4 A
VA Rating: 50.4
Features:
  • Dual Primary 115/230VAC
  • Operates on 50/60 Hz.
  • Combination solder or quick connect terminals.
  • Split bobbin construction eliminates the need for an electrostatic shield.
  • Hi-pot tested to 2 KV RMS.
  • Economical open style, channel frame - chassis mount design
  • UL recognized & CSA certified.
$19.53
Note: special order items require additional lead time. See our page on special order items.
P-T229D40 Transformer - Hammond, Power, Low Voltage PC Mount
Special Order Item
Size: 48 VA
Secondary Series: 40V C.T. @ 1.2A
Secondary Parallel: 20V @ 2.4 A
Features:
  • Low profile mounting, dual - split bobbin design.
  • Low primary to secondary coupling, balanced windings, no electrostatic shield required and low EMF radiation due to semi-toroidal design.
  • Universal dual primary 115/230V - 50/60 Hz.
  • High insulation - Hipot of 1,750V RMS.
  • Class B insulation - 130 degrees C.
  • C UL US recognized.
$30.35
Note: special order items require additional lead time. See our page on special order items.
P-T260X Transformer - Hammond, Plate & Filament
Special Order Item
  • Universal primary with taps for 100, 120, 220 or 240 VAC, 50 / 60 Hz. (Except the 260A6 which is 117V, 50/60 Hz only)
  • Designed for preamps, low power amps, general replacement, test equipment, etc.
  • Economical, open frame, chassis mount - two hole (.187 dia. = G) channel bracket (figure #1) or four hole mounting (figure #2).
  • Units include a Faraday shield between the primary and secondary windings. Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries.
  • Minimum 5" long leads.
  • For more selection check out our P-T300-X series of universal plate & filament transformers.
Starting at $76.76
Note: special order items require additional lead time. See our page on special order items.
P-T266G14 Transformer - Hammond, Power, Low voltage, 14V/0.5A
Special Order Item
Specifications:
  • Size: 7 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 14V @ 0.5 A
  • Secondary VAC RMS Parallel: 7V @ 1 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra p
$28.64
Note: special order items require additional lead time. See our page on special order items.
P-T266G36 Transformer - Hammond, Power, Low voltage, 36V/0.5A
Special Order Item
Specifications:
  • Size: 18 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 36V @ 0.5 A
  • Secondary VAC RMS Parallel: 18V @ 1 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra
$38.19
Note: special order items require additional lead time. See our page on special order items.
P-T266J14 Transformer - Hammond, Power, Low voltage, 14V/1A
Special Order Item
Specifications:
  • Size: 14 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 14V @ 1 A
  • Secondary VAC RMS Parallel: 7V @ 2 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra pr
$35.80
Note: special order items require additional lead time. See our page on special order items.
P-T266J48 Transformer - Hammond, Power, Low voltage, 48V/1A
Special Order Item
Specifications:
  • Size: 48 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 48V @ 1 A
  • Secondary VAC RMS Parallel: 24V @ 2 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra p
$35.80
Note: special order items require additional lead time. See our page on special order items.
P-T266M16 Transformer - Hammond, Power, Low voltage, 16V/3A
Special Order Item
Specifications:
  • Size: 48 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 16V @ 3 A
  • Secondary VAC RMS Parallel: 8V @ 6 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra pr
$38.19
Note: special order items require additional lead time. See our page on special order items.
P-T266N12 Transformer - Hammond, Power, Low voltage, 12.6V/4A
Special Order Item
Specifications:
  • Size: 50.4 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 12.6V @ 4 A
  • Secondary VAC RMS Parallel: 6.3V @ 8 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for ex
$40.57
Note: special order items require additional lead time. See our page on special order items.
P-T266PA6 Transformer - Hammond, Power, Low voltage, 6.3V/6A
Special Order Item
Specifications:
  • Size: 37.8 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 6.3V @ 6 A
  • Secondary VAC RMS Parallel: 3.15V @ 12 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for e
$47.73
Note: special order items require additional lead time. See our page on special order items.
P-T298DT Transformer - Hammond, Line Step Up Isolation, Toroidal, 500 VA
Special Order Item
Capacity: 500 VA
Dimensions: 9" long by 6" wide by 4" height
Features:
  • Primary 120VAC, 50/60 Hz., Secondary 240VAC.
  • Provides circuit isolation.
  • Toroidal transformer for high isolation, low noise, light weight cool operation and low profile.
  • 50 or 60 Hz.
$327.56
Note: special order items require additional lead time. See our page on special order items.
P-T298G4 Transformer - Hammond, Line European grounded adaptor plug
Special Order Item
Europeon plug type Used in: Austria; Belgium; Finland; France; Germany; Middle East; Netherlands; Norway; Parts of Africa, Asia ,South America, China, Tahiti and Caribbean; Sweden Features:
  • For use with Hammond transformers
  • Heavy duty design with plastic shell & double wipe contacts.
  • Indoor use only.
  • Allows for ground connection between equipment and international power sources.
  • Adaptors do not affect voltages, they are a mechanical device only to match foreign "pin-outs" of receptacles and/or plugs.
$10.38
Note: special order items require additional lead time. See our page on special order items.
P-T373AZ Transformer - Hammond, Power, 325-0-325 V, 46 mA, Univ. Primary
Special Order Item
  • Universal Primary - 100, 110, 120, 200, 220, 240 VAC 50/60 Hz.
  • High voltage secondary designed for full wave center tapped use.
  • 50 VAC bias tap from high voltage secondary C.T.
  • Black epoxy painted to match our P-T1650 series of output transformers .
  • Class A insulation (105 degrees C).
  • Hi-Pot tested to 2,500 VAC.
  • Windings are concentric wound for low stray field and low noise.

Secondary: 325-0-325 V, 46 mA Filament winding 1 : 5 VCT, 2 A Filament winding 2 : 6.3 VCT, 2 A Mounting centers: horizontal mount Weight: 2.5 lbs.
$122.78
Note: special order items require additional lead time. See our page on special order items.
P-T710-X Transformer - Hammond, High Voltage Plate, 115 VAC, 50 / 60 Hz
Special Order Item
  • Primary 115 VAC, 50 / 60 Hz.
  • At 2,000 VAC and above, secondary leads are through rubber bushings
  • Units can be run full wave bridge or full wave C.T.
  • V.A. is a C.C.S. rating
  • Current ratings are CCS (Continuous Commercial Service) & ICAS ratings (Intermittent Commercial or Amateur Service).
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Class A insulation (105 degrees C).
  • Hi-Pot test at a minimum of twice secondary voltage
  • Conservative designs - CSA certified (209651).
Starting at $95.75
Note: special order items require additional lead time. See our page on special order items.
P-T850LA Transformer - Hammond, Audio Broadcast Quality
Special Order Item
Output to Line, Matching or Bridging
  • Deep-drawn steel case with tin plated finish, with two convenient 6-32 mounting studs with mounting hardware.
  • Sealed case and wax potted core internally for stable characteristics and long life.
  • Wide frequency response ± 0.5 db max. from 20 Hz. to 20 Khz. (except units over 5K ohms impedance, may be down 1 db @ 20 Khz.)
  • Insertion loss of apx. 1 db.
  • Maximum power level +15 dbm. with specified characteristics, or higher levels with reduced low frequency performance.
  • Distortion is apx. 1.5% @ 20 Hz.
$146.22
Note: special order items require additional lead time. See our page on special order items.
P-RC-3 Choke - One Electron, Audio, PRC-3, 225H for Preamp Output
The PRC-3 audio choke from One Electron was designed as a plate load for the output of either a high quality line amplifier or a phono preamp.
$69.95
P-C1536X Choke - 0.17 - 250, Heavy Duty Hash Choke
Molded powdered iron core.
1-1/4 long axial leads.
High inductance & high current.
L measured at 1 Khz. Inductance: 250 µH20% tolerance
DC resistance ohms: .17
Self Resonant Frequency (MHz): 1.5
Maximum DC current amps: 2.5
Coil diameter (in): .43
Core Length (in): 1.25
$1.08
P-T119DA Transformer - Hammond, Audio Interstage, 12 Watt
Developed in response to requests from the Collins Collectors Association"this is a matching audio transformer for older equipment with 600 ohm audio outputdriving modern speakers. Or for "classic" high impedance speakers used with newer equipmentsimply swap primary for secondary (ie...4 or 8 ohm input and 600 ohms out). Key Features Isolation unit: (i.e.
$30.16
P-T125H Transformer - Hammond, Output, 8 W, 10k Primary
Specifications Audio Watts: 8 watts Primary Impendance (Ohms): 10K center-tapped Secondary Impendance (Ohms): 2/4/8 Mounting centers: 2-3/8u-bracket Weight: 1.0 lbs. Cat. No. Dimensions (Inches) A B C D G Mtg. Hole 125H 2.81 1.4 1.7 2.36 0.187
$37.00
P-T125J Transformer - Hammond, Output, 8 W, 2.5k or 4k Primary
Special Order Item
Specifications Audio Watts: 8 Primary Impendance (Ohms): 2.5k/4K center-tapped Secondary Impendance (Ohms): 6/8 - 3.2/4 Mounting centers: 2-13/16u-bracket Weight: 1.0 lb.
$35.23
Note: special order items require additional lead time. See our page on special order items.
P-T143 Transformer - Hammond, Power, 350-0-350V, 70-90 mA
Custom manufactured to replace most 6 and 7 tube sets of the early 1930s. Supplied with vertical mounting shells. Provides a seperate filament winding for audio output stages.
Specifications
Rating: 350-0-350 V, 70 or 90 mA (if 5 V winding is used with 2 A rectifier)
Windings: 5 V, 3 A; 2.5 V, 7.5 A; 2.5 VCT, 3.5 A
Mounting Centers:2 x 2.625"
Weight: 4.2 lbs.
Overall Height: 3.12"
$105.95
P-T166X-10 Transformer - Hammond, Low Voltage / Filament, Open, 10 VCT
Special Order Item
  • Primary 115 VAC, 60 Hz.
  • Secondary 10 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
Starting at $28.57
Save 21%
Originally: $36.37
Note: special order items require additional lead time. See our page on special order items.
P-T167X-12D6 Transformer - Hammond, Low Voltage / Filament, Enclosed, 12.6 VCT
Special Order Item
  • Primary 115 VAC, 60 Hz.
  • Secondary 12 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $29.73