Transformer - Marshall Replacement, Power for JTM45

Item Unavailable

Sorry! You are trying to check out one of our items which is no longer available. Why not check out one of these alternate options?

P-T290-MARSHALL Transformer - Hammond, Guitar Amplifier, replacement for Marshall
  • Replacements for Marshall amps
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Starting at $128.95
P-TM950P Transformer - Marshall, Power, 50 W, for JCM 900
Special Order Item
Genuine Marshall™ 50 watt power transformer for JCM900.
$115.00
Out of Stock
P-T290-FENDER-120 Transformer - Hammond, Guitar Amplifier, replacement for Fender, 120 V
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120-UP for upgraded 120 V transformers, P-T290-FENDER-240 for 240 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Starting at $57.49
P-T263-X Transformer - Hammond, High Voltage Plate & Filament, Vertical mount
  • Vertical Mount. For Horizontal Mount, see P-T263-Z
  • Primary 115 VAC, 60 Hz. - except as noted
  • Enclosed, 4 hole, chassis mount.
  • Minimum 6" long leads.
  • Units can be run full wave bridge or full wave C.T.
  • Class A insulation (105 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • Conservative designs - CSA certified (209651).
Starting at $64.90
Save 7%
Originally: $69.95
Partially Out of Stock
Note: P-T274AX: 720 V C.T. @ 138 mA is a special order item.
P-TGP-001 Transformer - Power, 120V Primary, 325/275V / 6.3VCT / 5V Secondary, for Fender® Champ
Power transformer replacement for the Fender® part numbers 125P1B, 022772, and 66079B. This transformer offers two different B+ options for lower voltage or higher voltage builds. This transformer is used in versions of the:
  • Bronco
  • Champ
  • Princeton
  • Princeton Reverb
  • Vibro Champ

Features
  • 275V or 325V (650/550 VCT) B+ options at 100mA
  • Center tapped 6.3V filament at 2.25A
  • 5V filament supply at 3A
  • For 120V 60Hz primary
  • Standard 2.5” x 2” mounting centers
$59.95
P-T166-6 Transformer - Hammond, Low Voltage / Filament, Open, 6.3 VCT
  • Open style, chassis mount transformers with a 115V 60Hz or 117 50/60Hz primary and a 6.3V center tapped secondary.
Starting at $13.25
Partially Out of Stock
Note:
P-T166E6:0.95
P-T166K6:7.56
are special order items.
Note: some of these items are special order items.
P-TN-68X Transformer - Isolation, 50 VA, 115V, 435 mA, 2 x 115V
An Isolation Power Transformer for isolating equipment from direct connection to the power line. The transformer is constructed with non-concentrically wound coils. The primary and secondary are wound on separate arbors, then assembled on a laminate core side-by-side separated by insulation. This prevents electrical connection, under normal or overload conditions, between the primary and secondary windings.
$23.49
P-T442 Transformer - Power, 117 V primary, 125 V @ 15 mA secondary
Specifications Primary 117 V, 50/60 Hz Secondary 125 V, 15 mA Filament Winding 12.6V, 0.3 A Mounting Centers 2" Mounting Type U-bracket Weight 0.7 lbs
$19.95
P-T300-X Transformer - Hammond, High Voltage Universal Plate & Filament, Vertical mount
  • Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
    • NOTE: units are designed to operate with BOTH primary windings engaged.
    • See primary wiring information under resources.
  • Bias Tap: 50 VAC tap from high voltage secondary C.T. (except part number P-T379WX - uses a separate 60VAC 0.2 Amp winding).
  • Highpot tested: 2,000 VAC
  • Faraday Copper Primary Shield: Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries (shield is internally grounded to the end bell).
  • Windings: Concentric wound for low stray field and low noise.
  • Models: This series is an upgrade from our P-T263-X range of units PLUS 2 models designed specifically for 300B tubes (Part Number P-T300BX) and 2A3 tubes (Part Number P-T302AX).
  • Finish: Black powder paint to match our P-T1650X series of output transformers Units can be run full wave bridge or full wave C.T.
  • Conservative designs - CSA certified (209651).
Starting at $90.06
Save 9%
Originally: $98.67
Partially Out of Stock
Note: P-T378CX: 800 V C.T. @ 535 mA is a special order item.
P-T292 Transformer - Power, 120V primary, 140/28/10.5 V secondary
  • Primary Voltage: 120 V
  • Secondary 1: 140 V @ 100 mA
  • Secondary 2: 28 V @ 20 mA
  • Secondary 3: 10.5 V @ 2 A

Primary voltage = black wires Secondary 1 = Red wires Secondary 2 = Yellow wires Secondary 3 = Green wires
$19.95
P-T261X6 Transformer - Hammond, Plate & Filament or Bias, 6.3 V auxiliary
  • Primary 115 VAC, 60 Hz.
  • Designed for small power or bias supplies, test equipment, preamps etc.
  • Models P-T261C6, P-T261E6, and P-T261G6 can also be used with full wave C.T. rectifiers.
  • Economical , two hole, channel bracket, chassis mount.
  • Minimum 5" long leads.
  • Convenient 6.3 filament/auxiliary winding.
Starting at $40.25
Note:
P-T262F6:120 V @ 140 mA
P-T261M6:215 V @ 269 mA
are special order items.
Note: some of these items are special order items.