Power Transformer - Hammond, 115V, 28VCT
Special Order Item
- Both series operate on ~\frac{50}{60}~ Hz current
- Low profile, split bobbin design.
- Dual winding secondaries, non-concentrically wound
- Units are designed so that all windings must be used
- Low primary to secondary coupling - no electrostatic shield required.
- High insulation - Hipot of 2,500V RMS.
- Class B insulation - 130 degrees C.
- c UL us recognized
Part No | Size | Secondary (RMS) | |
---|---|---|---|
Single Primary | |||
115V | VA | Series | Parallel |
P-T164F28 | 6 | 28V C.T. @ .2A | 14V @ .4A |
P-T164H28 | 20 | 28V C.T. @ .7A | 14V @ 1.4A |
SKU:
P-T164X-28
Item ID:
040013
Brand:
Hammond
RoHS Compliant
Capacity | Our Part Number | UPC/EAN | Hammond Part Number |
---|---|---|---|
6 VA | P-T164F28 | 623980261423 | 164F28 |
20 VA | P-T164H28 | 623980260389 | 164H28 |
Primary | 115 V @ 50 / 60 Hz | ||
Secondary, parallel | 6 VA version | P-T164F28 | 14 V @ 0.4 A |
20 VA version | P-T164H28 | 14 V @ 1.4 A | |
Secondary Series | 6 VA version | P-T164F28 | 28 V C.T. @ 0.2 A |
20 VA version | P-T164H28 | 28 V C.T. @ 0.7 A | |
VA Rating | 6 VA version | P-T164F28 | 6 |
20 VA version | P-T164H28 | 20 |
Packaging Dimensions | 6 VA version | P-T164F28 | 1.63 in. × 1.31 in. × 1.31 in. |
20 VA version | P-T164H28 | 2.25 in. × 1.88 in. × 1.44 in. | |
Weight (Packaging) | 6 VA version | P-T164F28 | 0.45 lbs. |
20 VA version | P-T164H28 | 0.87 lbs. |
P-T164F28 - 6 VA version | Primary | 115 V @ 50 / 60 Hz |
Secondary, parallel | 14 V @ 0.4 A | |
Secondary Series | 28 V C.T. @ 0.2 A | |
VA Rating | 6 | |
P-T164H28 - 20 VA version | Primary | 115 V @ 50 / 60 Hz |
Secondary, parallel | 14 V @ 1.4 A | |
Secondary Series | 28 V C.T. @ 0.7 A | |
VA Rating | 20 |