Clearance Items

- Vertical Mount. For Horizontal Mount, see P-T263-Z
- Primary 115 VAC, 60 Hz. - except as noted
- Enclosed, 4 hole, chassis mount.
- Minimum 6" long leads.
- Units can be run full wave bridge or full wave C.T.
- Class A insulation (105 degrees C).
- Hi-Pot test of 2,000V RMS.
- Conservative designs - CSA certified (209651).
Starting at $64.90
Save 7%
Originally: $69.95

- Open style, chassis mount transformers with a 115V 60Hz or 117 50/60Hz primary and a 6.3V center tapped secondary.
Starting at $13.25

- Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
- NOTE: units are designed to operate with BOTH primary windings engaged.
- See primary wiring information under resources.
- Bias Tap: 50 VAC tap from high voltage secondary C.T. (except part number P-T379WX - uses a separate 60VAC 0.2 Amp winding).
- Highpot tested: 2,000 VAC
- Faraday Copper Primary Shield: Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries (shield is internally grounded to the end bell).
- Windings: Concentric wound for low stray field and low noise.
- Models: This series is an upgrade from our P-T263-X range of units PLUS 2 models designed specifically for 300B tubes (Part Number P-T300BX) and 2A3 tubes (Part Number P-T302AX).
- Finish: Black powder paint to match our P-T1650X series of output transformers Units can be run full wave bridge or full wave C.T.
- Conservative designs - CSA certified (209651).
Starting at $63.83
Save 32%
Originally: $93.97

- Primary 115 VAC, 60 Hz.
- Designed for small power or bias supplies, test equipment, preamps etc.
- Models P-T261C6, P-T261E6, and P-T261G6 can also be used with full wave C.T. rectifiers.
- Economical , two hole, channel bracket, chassis mount.
- Minimum 5" long leads.
- Convenient 6.3 filament/auxiliary winding.
Starting at $40.25

Replacement for Bassman heads. Equivalent to #125A13A & #022871.
$53.58
Save 23%
Originally: $69.95

- Designed for drop in replacement of original units.
- Physically, parts were designed to look similar to original factory units (where possible).
- Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
- See P-T290-FENDER-120 for 120 V transformers, P-T290-Fender-120-UP for upgraded 120 V transformers
Warning: Not all amplifier models of the same name use the same transformer model.
Starting at $63.25

- Over designed for single ended tube output circuits (triode, tetrode or pentode tubes).
- Enclosed (shielded), 4 slot, above chassis Type 'X' mounting.
- Frequency response at least 20 Hz. to 20 Khz. at full rated power (± 1 db max. ref.
Starting at $145.41
Save 32%
Originally: $213.10

- Open style, chassis mount transformers with a 115V 60Hz primary and a 10V center tapped secondary
Starting at $15.98

Open style, chassis mount transformers with a 115V 60Hz or 117 50/60Hz primary and a 24V center tapped secondary.
Starting at $11.62

- Replacements for Yorkville/Traynor Amps
- Designed for drop in replacement of original units.
- Physically, parts were designed to look similar to original factory units (where possible).
- Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Starting at $58.13

- Primary 115 VAC, 60 Hz.
- Secondary 5 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
Starting at $40.75

- Single Primary 115VAC
- Operates on 50/60 Hz.
- Combination solder or quick connect terminals.
- Split bobbin construction eliminates the need for an electrostatic shield.
- Hi-pot tested to 2 KV RMS.
- Economical open style, channel frame - chassis mount design
- UL recognized & CSA certified.
Starting at $10.87

Deep-drawn steel case with tin plated finish, with two convenient 6-32 mounting studs with mounting hardware. Sealed case and wax potted core internally for stable characteristics and long life. Wide frequency response +/- 0.5 db max. from 20 Hz. to 20 Khz. (except units over 5K ohms impedance, may be down 1 db @ 20 Khz.) Insertion loss of apx. 1 db.
$161.22

- Open style, chassis mount transformers with a 115V 60Hz or 50/60Hz primary and an 18V center tapped secondary.
Starting at $11.68

- Primary 115 VAC, 60 Hz.
- Secondary 30 C.T.
- Center tapped secondary.
- Open style, channel bracket, two hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees, C).
- Hi-Pot test of 2,000 V RMS.
- UL listed (# E50394) & CSA certified (# LR3902).
Starting at $25.10
- Primary 115 VAC, 60 Hz.
- Secondary 60 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
$72.76

- Primary 115 VAC, 60 Hz.
- Secondary 12 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
Starting at $41.78

- Dual primary 115/230 VAC
- 50/60 Hz. operation
- Dual secondaries for series or parallel connections
- 4,000 V RMS Hipot test
- Class F insulation (155 degrees, C)
- Chassis mount
- Dual bobbin construction
- Dual use terminals
- C UL US recognized (E207860)
- TUV Type Approved
- CE certified to IEC 950 (Approved to EN 60-742 Safety Isolating Transformers)
$48.52